didingguanshididingshikeyizhunqueceliangdidingjixiaohaotijideboliyiqi,tashiyigenjuyoujingmikedu,neijingjunyundexichangboliguan,kelianxudegenjuxuyaofangchubutongtijideyeti,bingzhunqueduchuyetitijideliangqi。
根據長度和容積的不同,滴定管可分為常量滴定管、半微量滴定管和微量滴定管。
常量滴定管容積有50mL、25mL,刻度最小0.1mL,最小可讀到0.01mL。半微量滴定管容量10mL,刻度最小0.05mL,最小可讀到0.01mL。其結構一般與常量滴定管較為類似。微量滴定管容積有1mL、2mL、5mL、10mL,刻度最小0.01mL,最小可讀到0.001mL。此外還有半微量半自動滴定管,它可以自動加液,但滴定仍需手動控製。
滴定管一般分為兩種,酸式滴定管和堿式滴定管。
酸式滴定管又稱具塞滴定管,它的下端有玻璃旋塞開關,用來裝酸性溶液與氧化性溶液及鹽類溶液,不能裝堿性溶液如NaOH等(deng)。堿(jian)式(shi)滴(di)定(ding)管(guan)又(you)稱(cheng)無(wu)塞(sai)滴(di)定(ding)管(guan),它(ta)的(de)下(xia)端(duan)有(you)一(yi)根(gen)橡(xiang)皮(pi)管(guan),中(zhong)間(jian)有(you)一(yi)個(ge)玻(bo)璃(li)珠(zhu),用(yong)來(lai)控(kong)製(zhi)溶(rong)液(ye)的(de)流(liu)速(su),它(ta)用(yong)來(lai)裝(zhuang)堿(jian)性(xing)溶(rong)液(ye)與(yu)無(wu)氧(yang)化(hua)性(xing)溶(rong)液(ye),凡(fan)可(ke)與(yu)橡(xiang)皮(pi)管(guan)起(qi)作(zuo)用(yong)的(de)溶(rong)液(ye)均(jun)不(bu)可(ke)裝(zhuang)入(ru)堿(jian)式(shi)滴(di)定(ding)管(guan)中(zhong),如(ru)KMnO4,K2Cr2O7,dianyedeng。youyubupajiandejusifuyixihuosaideshiyong,kefuleputongsuanshididingguanpajiandequedian,shisuanshididingguankeyizuodaosuanjiantongyong,suoyijianshididingguandeshiyongdaweijianshao。womendeshiyanzhongjiushiyongzhezhongjusifuyixihuosaididingguan。
1、檢查試漏
didingguanxijinghou,xianjianzhaxuansaizhuandongshifoulinghuo,shifouloushui。xianguanbixuansai,jiangdidingguanchongmanshui,yonglvzhizaixuansaizhouweiheguanjianchujianzha。ranhoujiangxuansaixuanzhuan180度,直立兩分鍾,再用濾紙檢查。如漏水,酸式管塗凡士林;堿式滴定管使用前應先檢查橡皮管是否老化,檢查玻璃珠是否大小適當,若有問題,應及時更換活塞塗凡士林。
2、滴定管的洗滌
滴定管使用前必須先洗滌,洗滌時以不損傷內壁為原則。洗滌前,關閉旋塞,倒入約10mL洗液,打開旋塞,放出少量洗液洗滌管尖,然後邊轉動邊向管口傾斜,使洗液布滿全管。最後從管口放出(也可用鉻酸洗液浸洗)。然後用自來水衝淨。再用蒸餾水洗三次,每次10~15mL。
堿jian式shi滴di定ding管guan的de洗xi滌di方fang法fa與yu酸suan式shi滴di定ding管guan不bu同tong,堿jian式shi滴di定ding管guan可ke以yi將jiang管guan尖jian與yu玻bo璃li珠zhu取qu下xia,放fang入ru洗xi液ye浸jin洗xi。管guan體ti倒dao立li入ru洗xi液ye中zhong,用yong吸xi耳er球qiu將jiang洗xi液ye吸xi上shang洗xi滌di。
3、潤洗
滴定管在使用前還必須用操作溶液潤洗三次,每次10~15mL。潤洗液棄去。
4、裝液排氣泡
洗滌後再將操作溶液注入至零線以上,檢查活塞周圍是否有氣泡。若有,開大活塞使溶液衝出,排出氣泡。 滴定劑裝入必須直接注入,不能使用漏鬥或其他器皿輔助。
堿式滴定管排氣泡的方法:將堿式滴定管管體豎直,左手拇指捏住玻璃珠,使橡膠管彎曲,管尖斜向上約45度,擠壓玻璃珠處膠管,使溶液衝出,以排除氣泡。
5、讀初讀數
放出溶液後(裝滿或滴定完後)需(xu)等(deng)待(dai)一(yi)至(zhi)二(er)分(fen)鍾(zhong)後(hou)方(fang)可(ke)讀(du)數(shu)。讀(du)數(shu)時(shi),將(jiang)滴(di)定(ding)管(guan)從(cong)滴(di)定(ding)管(guan)架(jia)上(shang)取(qu)下(xia),左(zuo)手(shou)捏(nie)住(zhu)上(shang)部(bu)無(wu)液(ye)處(chu),保(bao)持(chi)滴(di)定(ding)管(guan)垂(chui)直(zhi)。視(shi)線(xian)與(yu)彎(wan)月(yue)麵(mian)最(zui)低(di)點(dian)刻(ke)度(du)水(shui)平(ping)線(xian)相(xiang)切(qie)。視(shi)線(xian)若(ruo)在(zai)彎(wan)月(yue)麵(mian)上(shang)方(fang),讀(du)數(shu)就(jiu)會(hui)偏(pian)高(gao);若在彎月麵下方,讀數就會偏低。 若為有色溶液,其彎月麵不夠清晰,則讀取液麵最高點。一般初讀數為0.00或0~1mL之間的任一刻度,以減小體積誤差。
有you的de滴di定ding管guan背bei麵mian有you一yi條tiao藍lan帶dai,稱cheng為wei藍lan帶dai滴di定ding管guan。藍lan帶dai滴di定ding管guan的de讀du數shu與yu普pu通tong滴di定ding管guan類lei似si,當dang藍lan帶dai滴di定ding管guan盛sheng溶rong液ye後hou將jiang有you兩liang個ge彎wan月yue麵mian相xiang交jiao,此ci交jiao點dian的de位wei置zhi即ji為wei藍lan帶dai滴di定ding管guan的de讀du數shu位wei置zhi。
1、滴定操作
滴定時,應將滴定管垂直地夾在滴定管夾上,滴定台應呈白色。滴定管離錐瓶口約1cm,用(yong)左(zuo)手(shou)控(kong)製(zhi)旋(xuan)塞(sai),拇(mu)指(zhi)在(zai)前(qian),食(shi)指(zhi)中(zhong)指(zhi)在(zai)後(hou),無(wu)名(ming)指(zhi)和(he)小(xiao)指(zhi)彎(wan)曲(qu)在(zai)滴(di)定(ding)管(guan)和(he)旋(xuan)塞(sai)下(xia)方(fang)之(zhi)間(jian)的(de)直(zhi)角(jiao)中(zhong)。轉(zhuan)動(dong)旋(xuan)塞(sai)時(shi),手(shou)指(zhi)彎(wan)曲(qu),手(shou)掌(zhang)要(yao)空(kong)。右(you)手(shou)三(san)指(zhi)拿(na)住(zhu)瓶(ping)頸(jing),瓶(ping)底(di)離(li)台(tai)約(yue)2~3cm,滴定管下端深入瓶口約1cm,微動右手腕關節搖動錐形瓶,邊滴邊搖使滴下的溶液混合均勻。搖動的錐瓶的規範方式為:youshouzhizhuipingjingbu,shouwanyonglishipingdiyanshunshizhenfangxianghuayuan,yaoqiushirongyezaizhuipingneijunyunxuanzhuan,xingchengxuanwo,rongyebunengyoutiaodong。guankouyuzhuipingyingwujiechu。
堿式滴定管操作方法:滴定時,以左手握住滴定管,拇指在前,食指在後,用其他指頭輔助固定管尖。 用拇指和食指捏住玻璃珠所在部位,向前擠壓膠管,使玻璃珠偏向手心,溶液就可以從空隙中流出。
2、滴定速度
液體流速由快到慢,起初可以“連滴成線”,之後逐滴滴下,快到終點時則要半滴半滴的加入。半滴的加入方法是:小心放下半滴滴定液懸於管口,用錐瓶內壁靠下,然後用用洗瓶衝下。
3、終點操作
當dang錐zhui瓶ping內nei指zhi示shi劑ji指zhi示shi終zhong點dian時shi,立li刻ke關guan閉bi活huo塞sai停ting止zhi滴di定ding。洗xi甁甁淋lin洗xi錐zhui形xing甁甁內nei壁bi。取qu下xia滴di定ding管guan,右you手shou執zhi管guan上shang部bu無wu液ye部bu分fen,使shi管guan垂chui直zhi,目mu光guang與yu液ye麵mian平ping齊qi,讀du出chu讀du數shu。讀du數shu時shi應ying估gu讀du一yi位wei。
滴定結束,滴定管內剩餘溶液應棄去,洗淨滴定管,夾在夾上備用。
1、滴定時,左手不允許離開活塞,放任溶液自己流下。
2、滴定時目光應集中在錐形瓶內的顏色變化上,不要去注視刻度變化,而忽略反應的進行。
3、 一般每個樣品要平行滴定三次,每次均從零線開始,每次均應及時記錄在實驗記錄表格上,不允許記錄到其他地方。
4、使用堿式滴定管注意事項
(1)用力方向要平,以避免玻璃珠上下移動。
(2)不要捏到玻璃珠下側部分,否則有可能使空氣進入管尖形成氣泡。
(3)擠壓膠管過程中不可過分用力,以避免溶液流出過快。
5、滴定也可在燒杯中進行,方法同上,但要用玻棒或電磁攪拌器攪拌。