1、設定容量值
一、簡介
yiyeqiangshiyiyeqideyizhong,changyongyushiyanshishaolianghuoweiliangyetideyiqu,tayougezhongbutongdeguige,rudantongdaoyiyeqianghuoduotongdaoyiyeqiang。zaizheliangzhongyiyeqiangxiayougezibaokuobutongdeliangcheng,ru0.1-2.5μL、0.5-10μL、10-100μL、20-200μL、100-1000μL等deng等deng。不bu同tong規gui格ge的de移yi液ye槍qiang配pei套tao使shi用yong不bu同tong大da小xiao的de槍qiang頭tou,不bu同tong生sheng產chan廠chang家jia生sheng產chan的de形xing狀zhuang也ye略lve有you不bu同tong,但dan工gong作zuo原yuan理li及ji操cao作zuo方fang法fa基ji本ben一yi致zhi。移yi液ye槍qiang屬shu精jing密mi儀yi器qi,使shi用yong及ji存cun放fang時shi均jun要yao小xiao心xin謹jin慎shen,防fang止zhi損sun壞huai,避bi免mian影ying響xiang其qi量liang程cheng。
二、移液槍的結構與工作原理
移液槍一般包括控製按鈕(不同廠家設計不同,通常也通過此按鈕進行吸液體積調節)、吸頭推卸按鈕、體積顯示窗、套筒、彈性吸嘴、吸頭。

圖1 移液槍結構示意圖
yiyeqideshizhishiyigehuosaishixiguan,liyongkongqipaifangyuanlijinxinggongzuo,yihuosaitaoneiyidongdejuliquedingyiyeqiangderongliang。yijuyiyemoshidebutong,kefenweineizhihuosaishiyiyemoshihewaizhihuosaishiyiyemoshi。womenrichangshiyongdeweineizhihuosaishiyiyemoshi。
內置活塞式移液模式的吸頭大多是通用的,但操作過程中比較容易發生交叉式汙染,並且不宜吸取高粘稠度液體、揮發性較大的液體;外(wai)置(zhi)活(huo)塞(sai)式(shi)移(yi)液(ye)模(mo)式(shi)中(zhong)活(huo)塞(sai)與(yu)液(ye)體(ti)之(zhi)間(jian)沒(mei)有(you)空(kong)氣(qi)段(duan),活(huo)塞(sai)為(wei)一(yi)次(ci)性(xing)的(de),對(dui)於(yu)粘(zhan)稠(chou)度(du)較(jiao)大(da)的(de)液(ye)體(ti),也(ye)能(neng)實(shi)現(xian)精(jing)確(que)移(yi)液(ye),另(ling)外(wai),由(you)於(yu)無(wu)空(kong)氣(qi)間(jian)隔(ge),避(bi)免(mian)了(le)樣(yang)品(pin)於(yu)空(kong)氣(qi)接(jie)觸(chu)可(ke)能(neng)發(fa)生(sheng)的(de)氣(qi)霧(wu)交(jiao)叉(cha)汙(wu)染(ran),因(yin)此(ci)非(fei)常(chang)適(shi)合(he)是(shi)珍(zhen)貴(gui)的(de)試(shi)劑(ji)、生物樣品的移取。
三、操作過程及注意事項
移液六部曲:設定容量值;裝槍頭;預洗槍頭;吸液;排液;退槍頭。

圖2 移液槍操作流程
操作之前請先選擇正確量程的移液槍,在吸頭最大量程的35-100%範圍內操作可提高操作準確性與重複性。量程調節可分為兩步:先xian進jin行xing粗cu調tiao,通tong過guo旋xuan轉zhuan按an鈕niu將jiang體ti積ji迅xun速su調tiao整zheng至zhi接jie近jin預yu想xiang值zhi。之zhi後hou進jin行xing細xi調tiao,將jiang移yi液ye槍qiang橫heng置zhi,通tong過guo調tiao節jie按an鈕niu慢man慢man調tiao至zhi預yu想xiang值zhi。當dang由you小xiao量liang程cheng調tiao節jie至zhi大da量liang程cheng時shi,朝chao所suo需xu量liang程cheng方fang向xiang連lian貫guan旋xuan轉zhuan,旋xuan轉zhuan到dao達da超chao過guo所suo需xu量liang程cheng1/3圈處再回調至所需量程,這樣可避免“機械回衝”,確que保bao更geng高gao準zhun確que性xing。當dang由you大da量liang程cheng調tiao節jie至zhi小xiao量liang程cheng時shi,直zhi接jie連lian貫guan旋xuan轉zhuan至zhi所suo需xu量liang程cheng。此ci步bu驟zhou需xu注zhu意yi,在zai調tiao節jie槍qiang的de過guo程cheng中zhong切qie忌ji超chao過guo最zui大da或huo最zui小xiao量liang程cheng,以yi免mian損sun害hai移yi液ye槍qiang的de精jing確que度du。
2、裝槍頭
移yi液ye槍qiang頂ding端duan插cha入ru槍qiang頭tou,套tao柄bing用yong力li下xia壓ya,需xu要yao時shi小xiao幅fu度du旋xuan轉zhuan即ji可ke。注zhu意yi不bu可ke用yong力li敲qiao擊ji吸xi頭tou。此ci操cao作zuo會hui使shi槍qiang頭tou損sun壞huai,甚shen至zhi造zao成cheng移yi液ye槍qiang套tao柄bing磨mo損sun,從cong而er影ying響xiang其qi密mi封feng性xing。
3、預洗槍頭
yongtongyiyangpinzhongfuxiyepaiyeerzhisanci。duiyuweiliangyiyeqi,gaicaozuoyouzhuyuneibixifu,bingqiekeyishidaliangchengxitouneibudekongqidengyuyangpinwendu,baozhengcaozuodeyizhixing。zhuyigaowenhuozhediwenyetiqingbuyaorunxi。

圖3 預洗槍頭操作
4、吸液
先將移液槍排放按鈕按至第一停點,再將槍頭盡量保持垂直狀態浸入液麵,保持移液器在與垂直角度成20°範圍內。槍頭浸入深度可參考圖七中所示建議深度,浸入太深會吸入過多的液體;相反,槍頭位置過於接近表麵會吸入空氣;兩種操作都會造成吸入量不準確。吸液時保持勻速連貫移液,控製好移液速度。快速或不平穩的吸液會使液體噴濺,產生氣霧、套柄汙染以及樣品損失。吸液後在液麵中保持一秒鍾再將槍頭平緩移開,並輕靠器壁去除槍頭外壁掛存的液體。

圖4 吸液時槍頭浸入深度與節奏


圖5 保持正確吸液速度
5、排液
排pai液ye時shi首shou先xian確que認ren槍qiang頭tou內nei無wu氣qi泡pao,槍qiang頭tou尖jian輕qing靠kao容rong器qi內nei壁bi,排pai出chu剩sheng餘yu樣yang品pin,之zhi後hou使shi其qi沿yan容rong器qi內nei壁bi向xiang上shang滑hua動dong,避bi免mian液ye體ti粘zhan在zai槍qiang頭tou口kou上shang。圖tu九jiu所suo示shi另ling外wai兩liang種zhong技ji巧qiao同tong樣yang適shi用yong於yu水shui溶rong(非粘性)液。
圖6 排液操作方法

6、退槍頭
按動槍頭推卸按鈕卸掉使用過的槍頭。注意與新槍頭分開放置,以免發生交叉汙染。移液槍使用後調回最大量程。
在使用移液槍時也應注意溫度對移液準確性的影響。如理想的移液溫度是21.5℃(±1℃)。儀yi器qi和he樣yang品pin的de溫wen度du應ying與yu工gong作zuo的de室shi溫wen相xiang同tong,並bing且qie要yao避bi開kai可ke導dao致zhi大da幅fu或huo突tu然ran溫wen度du變bian化hua的de通tong風feng或huo陽yang光guang照zhao射she區qu域yu。另ling外wai,經jing過guo長chang時shi間jian的de移yi液ye,手shou上shang的de溫wen度du會hui使shi移yi液ye槍qiang變bian熱re,移yi液ye槍qiang內nei部bu空kong氣qi膨peng脹zhang,也ye會hui導dao致zhi結jie果guo不bu準zhun確que。因yin此ci在zai兩liang次ci移yi液ye操cao作zuo之zhi間jian,應ying將jiang移yi液ye槍qiang放fang回hui支zhi架jia,以yi避bi免mian手shou溫wen對dui移yi液ye的de影ying響xiang。
文章來源:網絡轉載;
手機版